Assessment Year 1995
Principal Product Frozen Fruit Pies
NAICS
n/a
SIC 2038: Frozen Specialties, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 100
Plant Area 16,000
ft2
Annual Production 10,000,000
lb
Production Hrs. Annual 2,000
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $173,138 2,983,001
kWh
LPG $30,984 5,154
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $79,397 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $1,481

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings LPG Savings Primary Product Savings
01 2.4111: Utilize energy-efficient belts and other improved mechanisms $380 $31 $380
6,155
kWh
- -
02 2.2136: Install / repair insulation on steam lines $884 $468 - $884
-
MMBtu
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,037 $276 $1,037
15,533
kWh
- -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $667 $532 $667
4,396
kWh
- -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $217 $980 $217
3,517
kWh
- -
06 2.2612: Use cooling tower water instead of refrigeration $64,115 $12,675 $64,115
1,038,101
kWh
- -
07 2.5194: Redesign process $12,097 $15,250 $(-3,263.0)
(-54,220)
kWh
- $15,360
TOTAL RECOMMENDED $79,397 $30,212 $63,153
1,013,482
kWh
$884
-
MMBtu
$15,360
TOTAL IMPLEMENTED $1,481 $1,479 $597
9,672
kWh
$884
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings LPG Savings Primary Product Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs