Assessment Year | 2022 |
---|---|
Principal Product | hand held surgical instruments |
NAICS | 339112: Surgical and Medical Instrument Manufacturing |
SIC | 3841: Surgical and Medical Instruments and Apparatus |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
60,000
ft2
|
Annual Production | 111,000
pieces
|
Production Hrs. Annual | 2,375
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $97,177 | 1,124,400 |
kWh
|
$0.086 |
Electricity Demand | $15,567 | 4,751 |
kW-mo/yr
|
$3.28 |
Natural Gas | $9,768 | 1,312 |
MMBtu
|
$7.45 |
TOTAL YEARLY COSTS | $122,512 | |||
RECOMMENDED SAVINGS* | $23,341 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,095 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.7221: Lower temperature during the winter season and vice-versa | $382 | $240 |
$325
3,783
kWh
|
$56
-
kW-mo/yr
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,529 | $20,439 |
$3,157
36,707
kWh
|
$869
-
kW-mo/yr
|
$3,503 | |
03 | 2.4239: Eliminate or reduce compressed air usage | $540 | $3,202 |
$453
5,262
kWh
|
$87
-
kW-mo/yr
|
- | |
04 | 2.7232: Replace existing hvac unit with high efficiency model | $11,471 | $60,924 |
$9,418
109,515
kWh
|
$2,053
-
kW-mo/yr
|
- | |
05 | 2.2511: Insulate bare equipment | $583 | $960 |
$583
6,770
kWh
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $983 | $150 |
$805
9,365
kWh
|
$178
-
kW-mo/yr
|
- | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,853 | $4,331 |
$1,853
21,541
kWh
|
- | - | |
TOTAL RECOMMENDED | $23,341 | $90,246 |
$16,594
192,943
kWh
|
$3,243
-
kW-mo/yr
|
$3,503 | ||
TOTAL IMPLEMENTED | $9,095 | $21,549 |
$4,545
52,842
kWh
|
$1,047
-
kW-mo/yr
|
$3,503 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs