Assessment Year | 2020 |
---|---|
Principal Product | Shot Blasters, Washers & Vibrator Equipment |
NAICS | 333249: Other Industrial Machinery Manufacturing |
SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 34 |
Plant Area |
52,000
ft2
|
Annual Production | 210
units
|
Production Hrs. Annual | 2,250
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $69,908 | 728,618 |
kWh
|
$0.096 |
Electricity Demand | $36,088 | 5,970 |
kW-mo/yr
|
$6.04 |
TOTAL YEARLY COSTS | $105,996 | |||
RECOMMENDED SAVINGS* | $29,150 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $12,533 | $24,500 |
$9,381
97,810
kWh
|
$3,152
-
kW-mo/yr
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,790 | $7,081 |
$4,334
45,191
kWh
|
$1,456
-
kW-mo/yr
|
|
03 | 2.7135: Install occupancy sensors | $5,169 | $10,500 |
$3,869
40,339
kWh
|
$1,300
-
kW-mo/yr
|
|
04 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $3,201 | $3,250 | - |
$3,201
-
kW-mo/yr
|
|
05 | 2.7134: Use photocell controls | $1,385 | $1,440 |
$936
9,765
kWh
|
$449
-
kW-mo/yr
|
|
06 | 2.4322: Use or replace with energy efficient substitutes | $1,072 | $2,400 |
$798
8,310
kWh
|
$274
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $29,150 | $49,171 |
$19,318
201,415
kWh
|
$9,832
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs