Assessment Year | 2016 |
---|---|
Principal Product | Automotive service equipment |
NAICS | 334515: Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals |
SIC | 3825: Instruments for Measuring and Testing of Electricity and Electrical Signals |
Sales Range | $10 M to 50M |
# of Employees | 205 |
Plant Area |
207,000
ft2
|
Annual Production | 40,000
units
|
Production Hrs. Annual | 2,125
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $271,798 | 3,305,007 |
kWh
|
$0.082 |
Electricity Demand | $22,613 | 8,975 |
kW-mo/yr
|
$2.52 |
Natural Gas | $88,087 | 7,914 |
MMBtu
|
$11.13 |
TOTAL YEARLY COSTS | $382,498 | |||
RECOMMENDED SAVINGS* | $71,353 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $35,384 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 4.512: Condense operation into one building | $4,197 | $900 |
$4,197
51,060
kWh
|
- | - | |
02 | 2.7221: Lower temperature during the winter season and vice-versa | $27,674 | $30,000 |
$25,704
312,699
kWh
|
$1,970
-
kW-mo/yr
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $23,739 | $80,500 |
$20,236
246,181
kWh
|
$3,503
-
kW-mo/yr
|
- | |
04 | 2.7135: Install occupancy sensors | $6,607 | $3,000 |
$6,607
80,385
kWh
|
- | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $841 | $1,100 |
$717
8,719
kWh
|
$124
-
kW-mo/yr
|
- | |
06 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $7,627 | $20,000 | - | - |
$7,627
-
MMBtu
|
|
07 | 2.2511: Insulate bare equipment | $668 | $600 | - | - |
$668
-
MMBtu
|
|
TOTAL RECOMMENDED | $71,353 | $136,100 |
$57,461
699,044
kWh
|
$5,597
-
kW-mo/yr
|
$8,295
-
MMBtu
|
||
TOTAL IMPLEMENTED | $35,384 | $85,500 |
$31,757
386,345
kWh
|
$3,627
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs