Assessment Year | 2014 |
---|---|
Principal Product | cement |
NAICS | 327310: Cement Manufacturing |
SIC | 3241: Cement, Hydraulic |
Sales Range | $100 M to 500M |
# of Employees | 105 |
Plant Area |
2,000,000
ft2
|
Annual Production | 2,100,000
ton
|
Production Hrs. Annual | 8,700
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $8,011,619 | 221,935,612 |
kWh
|
$0.036 |
Electricity Demand | $4,662,123 | 402,323 |
kW-mo/yr
|
$11.59 |
Natural Gas | $334,000 | 85,000 |
MMBtu
|
$3.93 |
Coal | $8,000,000 | 5,003,800 |
MMBtu
|
$1.60 |
Other Energy | $260,000 | 9,466 |
MMBtu
|
$27.47 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,565,723 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Energy Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3412: Use waste heat to produce steam to drive a steam turbine-generator | $5,306,536 | $18,000,000 |
$3,664,980
101,523,000
kWh
|
$1,641,556
-
kW-mo/yr
|
- | - | |
02 | 3.1161: Eliminate/reduce an operation | $218,015 | - |
$150,573
4,171,000
kWh
|
$67,442
-
kW-mo/yr
|
- | - | |
03 | 2.2511: Insulate bare equipment | $66,528 | $339,300 |
$45,948
1,272,800
kWh
|
$20,580
-
kW-mo/yr
|
- | - | |
04 | 4.445: Install equipment to move product | $974,644 | $3,131,120 |
$(-70,771.0)
(-1,960,488)
kWh
|
$(-31,125.0)
-
kW-mo/yr
|
$230,736
-
MMBtu
|
$845,804 | |
TOTAL RECOMMENDED | $6,565,723 | $21,470,420 |
$3,790,730
105,006,312
kWh
|
$1,698,453
-
kW-mo/yr
|
$230,736
-
MMBtu
|
$845,804 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs