Assessment Year | 2022 |
---|---|
Principal Product | Iron casting provider (foundry) |
NAICS | 331511: Iron Foundries |
SIC | 3321: Gray and Ductile Iron Foundries |
Sales Range | $10 M to 50M |
# of Employees | 230 |
Plant Area |
170,000
ft2
|
Annual Production | 15,900
ton
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $963,264 | 21,279,945 |
kWh
|
$0.045 | |
Electricity Demand | $846,552 | 51,950 |
kW-mo/yr
|
$16.30 | |
Electricity Fees | $(-109,719.0) | - |
|
- | |
Natural Gas | $787,876 | 156,714 |
MMBtu
|
$5.03 | |
Waste Disposal Costs | |||||
Water Usage | $241,635 | 30,077 |
Tgal
|
$8.03 | |
TOTAL YEARLY COSTS | $2,729,608 | ||||
RECOMMENDED SAVINGS* | $47,213 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $45,007 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $306 | $40 |
$204
4,528
kWh
|
$102
-
kW-mo/yr
|
|
02 | 2.7134: Use photocell controls | $386 | $133 |
$258
5,731
kWh
|
$128
-
kW-mo/yr
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $45,007 | $800 |
$17,861
396,914
kWh
|
$27,146
-
kW-mo/yr
|
|
04 | 2.6211: Conserve energy by efficient use of vending machines | $1,514 | $610 |
$1,012
22,491
kWh
|
$502
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $47,213 | $1,583 |
$19,335
429,664
kWh
|
$27,878
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $45,007 | $800 |
$17,861
396,914
kWh
|
$27,146
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs