Assessment Year | 2025 |
---|---|
Principal Product | Automated Truck Arms |
NAICS | 336211: Motor Vehicle Body Manufacturing |
SIC | 3713: Truck and Bus Bodies |
Sales Range | $10 M to 50M |
# of Employees | 71 |
Plant Area |
33,750
ft2
|
Annual Production | 1,140
units
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $46,933 | 598,500 |
kWh
|
$0.078 | |
Electricity Demand | $45,270 | 3,600 |
kW-mo/yr
|
$12.58 | |
Electricity Fees | $1,119 | - |
|
- | |
LPG | $18,700 | 2,265 |
MMBtu
|
$8.26 | |
Waste Disposal Costs | |||||
Water Usage | $1,243 | 1,640 |
Tgal
|
$0.76 | |
Water Disposal | $934 | 1,164 |
Tgal
|
$0.80 | |
TOTAL YEARLY COSTS | $114,199 | ||||
RECOMMENDED SAVINGS* | $203,996 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.1321: Replace fossil fuel equipment with electrical equipment | $15,878 | $75,000 |
$(-2,822.0)
(-36,000)
kWh
|
$18,700
-
MMBtu
|
- | |
02 | 2.9114: Use solar heat to make electricty | $17,043 | $161,000 |
$17,043
217,043
kWh
|
- | - | |
03 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $675 | $2,667 |
$675
8,604
kWh
|
- | - | |
04 | 2.8212: Reduce delivery schedules | $170,400 | $21,600 | - | - | $170,400 | |
TOTAL RECOMMENDED | $203,996 | $260,267 |
$14,896
189,647
kWh
|
$18,700
-
MMBtu
|
$170,400 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs