| Assessment Year | 2011 |
|---|---|
| Principal Product | upolstered motion furniture |
| NAICS | 337121: Upholstered Household Furniture Manufacturing |
| SIC | 2512: Wood Household Furniture, Upholstered |
| Sales Range | $100 M to 500M |
| # of Employees | 250 |
| Plant Area |
550,000
ft2
|
| Annual Production | 304,215
units
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $647,600 | 11,376,000 |
kWh
|
$0.057 |
| Electricity Demand | $514,195 | 33,349 |
kW-mo/yr
|
$15.42 |
| Electricity Fees | $(-74,197.0) | - |
|
- |
| Natural Gas | $37,554 | 4,354 |
MMBtu
|
$8.63 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $44,055 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $35,336 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.2437: Recover waste heat from equipment | $7,135 | $6,411 | - | - | - |
$7,135
-
MMBtu
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $19,874 | $139,671 |
$9,619
168,960
kWh
|
$9,961
-
kW-mo/yr
|
$294 | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,458 | $26,246 |
$4,773
83,835
kWh
|
$2,575
-
kW-mo/yr
|
$110 | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,247 | $33,997 |
$3,424
60,147
kWh
|
$3,716
-
kW-mo/yr
|
$107 | - | |
| 05 | 2.7124: Make a practice of turning off lights when not needed | $1,584 | $659 |
$1,561
27,410
kWh
|
- | $23 | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $757 | $281 |
$746
12,901
kWh
|
- | $11 | - | |
| TOTAL RECOMMENDED | $44,055 | $207,265 |
$20,123
353,253
kWh
|
$16,252
-
kW-mo/yr
|
$545 |
$7,135
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $35,336 | $200,195 |
$18,562
325,843
kWh
|
$16,252
-
kW-mo/yr
|
$522 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs