Assessment Year | 2008 |
---|---|
Principal Product | Motors |
NAICS | 335312: Motor and Generator Manufacturing |
SIC | 3621: Motors and Generators |
Sales Range | $10 M to 50M |
# of Employees | 85 |
Plant Area |
290,000
ft2
|
Annual Production | 8,750
pieces
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $148,298 | 1,968,200 |
kWh
|
$0.075 |
Electricity Fees | $23,477 | - |
|
- |
Natural Gas | $83,647 | 6,948 |
MMBtu
|
$12.04 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $129,482 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $129,482 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $88,210 | $108,210 |
$82,439
1,095,674
kWh
|
$5,771 | |
02 | 2.7135: Install occupancy sensors | $38,485 | $2,400 |
$35,967
478,033
kWh
|
$2,518 | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,787 | $236 |
$2,605
34,617
kWh
|
$182 | |
TOTAL RECOMMENDED | $129,482 | $110,846 |
$121,011
1,608,324
kWh
|
$8,471 | ||
TOTAL IMPLEMENTED | $129,482 | $110,846 |
$121,011
1,608,324
kWh
|
$8,471 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs