| Assessment Year | 2003 |
|---|---|
| Principal Product | Potted plants |
| NAICS | 111422: Floriculture Production |
| SIC | 181: |
| Sales Range | $1 M to 5M |
| # of Employees | 30 |
| Plant Area |
230,062
ft2
|
| Annual Production | 225,000
pieces
|
| Production Hrs. Annual | 3,640
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $34,208 | 466,560 |
kWh
|
$0.073 |
| Electricity Fees | $513 | - |
|
- |
| Natural Gas | $104,811 | 20,643 |
MMBtu
|
$5.08 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $60,363 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $60,123 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Wood Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.1224: Replace boiler | $60,123 | $97,000 | - | - |
$91,059
-
MMBtu
|
$(-15,936.0)
-
MMBtu
|
$(-15,000.0) | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $240 | $450 |
$236
3,295
kWh
|
$4 | - | - | - | |
| TOTAL RECOMMENDED | $60,363 | $97,450 |
$236
3,295
kWh
|
$4 |
$91,059
-
MMBtu
|
$(-15,936.0)
-
MMBtu
|
$(-15,000.0) | ||
| TOTAL IMPLEMENTED | $60,123 | $97,000 | - | - |
$91,059
-
MMBtu
|
$(-15,936.0)
-
MMBtu
|
$(-15,000.0) | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs