Assessment Year | 2003 |
---|---|
Principal Product | Potted plants |
NAICS | 111422: Floriculture Production |
SIC | 181: |
Sales Range | $1 M to 5M |
# of Employees | 30 |
Plant Area |
230,062
ft2
|
Annual Production | 225,000
pieces
|
Production Hrs. Annual | 3,640
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $34,208 | 466,560 |
kWh
|
$0.073 |
Electricity Fees | $513 | - |
|
- |
Natural Gas | $104,811 | 20,643 |
MMBtu
|
$5.08 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $60,363 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $60,123 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Wood Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.1224: Replace boiler | $60,123 | $97,000 | - | - |
$91,059
-
MMBtu
|
$(-15,936.0)
-
MMBtu
|
$(-15,000.0) | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $240 | $450 |
$236
3,295
kWh
|
$4 | - | - | - | |
TOTAL RECOMMENDED | $60,363 | $97,450 |
$236
3,295
kWh
|
$4 |
$91,059
-
MMBtu
|
$(-15,936.0)
-
MMBtu
|
$(-15,000.0) | ||
TOTAL IMPLEMENTED | $60,123 | $97,000 | - | - |
$91,059
-
MMBtu
|
$(-15,936.0)
-
MMBtu
|
$(-15,000.0) |