Assessment Year | 1996 |
---|---|
Principal Product | File Folders, Computer Paper, and Paper Pads |
NAICS |
n/a
|
SIC | 2652: Setup Paperboard Boxes |
Sales Range | $10 M to 50M |
# of Employees | 156 |
Plant Area |
294,000
ft2
|
Annual Production | 26,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $215,464 | 5,021,395 |
kWh
|
$0.043 |
Electricity Demand | $37,683 | 11,008 |
kW-mo/yr
|
$3.42 |
Electricity Fees | $80,360 | - |
|
- |
Natural Gas | $59,392 | 12,857 |
MMBtu
|
$4.62 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $53,153 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $44,638 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $5,086 | $3,378 | - | - | - |
$5,086
-
MMBtu
|
- | - | |
02 | 2.7134: Use photocell controls | $3,429 | $402 |
$2,898
65,944
kWh
|
- | $531 | - | - | - | |
03 | 2.6214: Shut off pilots in standby equipment | $2,600 | $120 | - | - | - |
$2,600
-
MMBtu
|
- | - | |
04 | 2.7122: Disconnect ballasts | $2,838 | $40 |
$2,097
47,773
kWh
|
$238
-
kW-mo/yr
|
$503 | - | - | - | |
05 | 3.1192: Reduce scrap production | $39,200 | $2,000 | - | - | - | - |
$(-5,600.0)
-
lb
|
$44,800 | |
TOTAL RECOMMENDED | $53,153 | $5,940 |
$4,995
113,717
kWh
|
$238
-
kW-mo/yr
|
$1,034 |
$7,686
-
MMBtu
|
$(-5,600.0)
-
lb
|
$44,800 | ||
TOTAL IMPLEMENTED | $44,638 | $2,160 |
$2,097
47,773
kWh
|
$238
-
kW-mo/yr
|
$503 |
$2,600
-
MMBtu
|
$(-5,600.0)
-
lb
|
$44,800 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs