Assessment Year | 1996 |
---|---|
Principal Product | electric motors |
NAICS |
n/a
|
SIC | 3621: Motors and Generators |
Sales Range | $50 M to 100M |
# of Employees | 650 |
Plant Area |
250,000
ft2
|
Annual Production | 4,080,000
pieces
|
Production Hrs. Annual | 5,760
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $403,214 | 13,048,652 |
kWh
|
$0.031 |
Electricity Demand | $283,634 | 27,920 |
kW-mo/yr
|
$10.16 |
Electricity Fees | $10,453 | - |
|
- |
Natural Gas | $281,924 | 45,933 |
MMBtu
|
$6.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $63,011 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,642 | $54,665 |
$10,300
333,236
kWh
|
$7,342
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.7124: Make a practice of turning off lights when not needed | $9,466 | $1,785 |
$9,466
306,272
kWh
|
- | - | - | - | - | |
03 | 2.7227: Use water on air conditioning exchanger to improve heat transfer and increase air conditioner efficiency | $7,857 | $9,300 |
$5,664
183,177
kWh
|
$2,193
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.2414: Use waste heat from hot flue gases to preheat | $13,169 | $3,000 | - | - |
$13,169
-
MMBtu
|
- | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,437 | $3,495 |
$749
24,326
kWh
|
$688
-
kW-mo/yr
|
- | - | - | - | |
06 | 3.7196: Use re-usable filters | $11,040 | $12,000 | - | - | - | - | $(-960.0) | $12,000 | |
07 | 3.8142: Distill contaminated solvents for reuse | $2,400 | $6,000 |
$(-7.0)
(-293)
kWh
|
$(-127.0)
-
kW-mo/yr
|
- |
$3,469
-
gal
|
$(-935.0) | - | |
TOTAL RECOMMENDED | $63,011 | $90,245 |
$26,172
846,718
kWh
|
$10,096
-
kW-mo/yr
|
$13,169
-
MMBtu
|
$3,469
-
gal
|
$(-1,895.0) | $12,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs