Assessment Year | 2009 |
---|---|
Principal Product | Canned Seafood |
NAICS | 311710: Seafood Product Preparation and Packaging |
SIC | 2091: Canned and Cured Fish and Seafoods |
Sales Range | $10 M to 50M |
# of Employees | 325 |
Plant Area |
200,000
ft2
|
Annual Production | 25,000,000
lb
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | Puerto Rico |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,107,648 | 6,433,416 |
kWh
|
$0.17 |
Electricity Demand | $129,720 | 16,847 |
kW-mo/yr
|
$7.70 |
Electricity Fees | $5,400 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $116,250 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $110,583 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #6 Savings |
---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $60,788 | $640 |
$52,811
528,156
kWh
|
$7,977
-
kW-mo/yr
|
- | |
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $34,867 | $1,500 | - | - |
$34,867
-
MMBtu
|
|
03 | 2.4323: Use optimum size and capacity equipment | $9,578 | $320 |
$8,316
48,917
kWh
|
$1,262
-
kW-mo/yr
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,667 | $80 |
$4,818
28,343
kWh
|
$849
-
kW-mo/yr
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,350 | $920 |
$4,882
28,715
kWh
|
$468
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $116,250 | $3,460 |
$70,827
634,131
kWh
|
$10,556
-
kW-mo/yr
|
$34,867
-
MMBtu
|
||
TOTAL IMPLEMENTED | $110,583 | $3,380 |
$66,009
605,788
kWh
|
$9,707
-
kW-mo/yr
|
$34,867
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs