Assessment Year 2007
Principal Product Medical Plastic Products
NAICS 326199: All Other Plastics Product Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area 30,000
ft2
Annual Production 367,000,000
pieces
Production Hrs. Annual 8,400
hrs
Location (State) Puerto Rico

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $727,679 5,313,000
kWh
Electricity Demand $84,826 10,736
kW-mo/yr
Electricity Fees $473 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $140,526 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $91,231

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.2136: Install / repair insulation on steam lines $46,436 $1,955 $46,128
329,484
kWh
$308
-
kW-mo/yr
02 2.7221: Lower temperature during the winter season and vice-versa $67,528 $120 $62,440
446,021
kWh
$5,088
-
kW-mo/yr
03 2.7142: Utilize higher efficiency lamps and/or ballasts $19,594 $20,498 $18,184
129,886
kWh
$1,410
-
kW-mo/yr
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,109 $1,074 $3,869
27,639
kWh
$240
-
kW-mo/yr
05 2.4323: Use optimum size and capacity equipment $1,528 $3,010 $1,424
9,429
kWh
$104
-
kW-mo/yr
06 2.4231: Reduce the pressure of compressed air to the minimum required $1,331 $30 $1,183
8,450
kWh
$148
-
kW-mo/yr
TOTAL RECOMMENDED $140,526 $26,687 $133,228
950,909
kWh
$7,298
-
kW-mo/yr
TOTAL IMPLEMENTED $91,231 $21,692 $84,493
603,546
kWh
$6,738
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs