Assessment Year 2007
Principal Product Newspapers
NAICS 511110: Newspaper Publishers
SIC 2711: Newspapers: Publishing, or Publishing and Printing
Sales Range $50
M
to 100
M
# of Employees 450
Plant Area 350,000
ft2
Annual Production 70,000,000
pieces
Production Hrs. Annual 8,760
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,287,669 18,740,398
kWh
Electricity Demand $400,042 40,245
kW-mo/yr
Electricity Fees $147,201 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $226,415 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $70,318

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Water Consumption Savings
01 2.2628: Utilize a less expensive cooling method $127,674 $105,070 $105,825
1,511,782
kWh
$21,849
-
kW-mo/yr
-
02 2.4231: Reduce the pressure of compressed air to the minimum required $37,375 $30 $30,572
436,736
kWh
$6,803
-
kW-mo/yr
-
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $18,482 $1,074 $18,182
265,042
kWh
$300
-
kW-mo/yr
-
04 2.2447: Heat water with exhaust heat $14,461 $1,349 $11,908
176,082
kWh
$2,553
-
kW-mo/yr
-
05 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $13,799 $14,700 $11,436
163,374
kWh
$2,363
-
kW-mo/yr
-
06 2.7134: Use photocell controls $6,838 $770 $5,211
77,482
kWh
$1,627
-
kW-mo/yr
-
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $5,866 $2,373 $5,762
82,741
kWh
$104
-
kW-mo/yr
-
08 3.4116: Meter recycled water (to reduce sewer charges) $1,920 $4,160 - - $1,920
-
Tgal
TOTAL RECOMMENDED $226,415 $129,526 $188,896
2,713,239
kWh
$35,599
-
kW-mo/yr
$1,920
-
Tgal
TOTAL IMPLEMENTED $70,318 $2,453 $60,662
877,860
kWh
$9,656
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Water Consumption Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs