ITAC Assessment: MI0108
ITAC logo
ITAC Assessment: MI0108
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2005
Principal Product Glass Curtain Wall
NAICS 332321: Metal Window and Door Manufacturing
SIC 3449: Miscellaneous Structural Metal Work
Sales Range $10
M
to 50
M
# of Employees 110
Plant Area 106,000
ft2
Annual Production 800
thousand feet
Production Hrs. Annual 2,250
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $50,012 848,370
kWh
Electricity Demand $16,873 2,028
kW-mo/yr
Electricity Fees $9,559 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $124,657 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Personnel Changes Savings Administrative Changes Savings Primary Raw Material Savings Ancillary Material Cost Savings
01 3.7214: Reduce or eliminate waste $89,286 $5,260 - - - $90,000 $(-714.0)
02 3.5316: Contract a wood pallet recycling company $24,230 $5,100 $722
13,055
kWh
$(-5,360.0) $29,118 - $(-250.0)
03 2.6218: Turn off equipment when not in use $8,363 $120 $8,363
150,783
kWh
- - - -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,902 $50 $1,902
34,342
kWh
- - - -
05 2.7111: Reduce illumination to minimum necessary levels $320 $320 $320
16,813
kWh
- - - -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $556 $556 $1,074
12,929
kWh
$(-168.0) - - $(-350.0)
TOTAL RECOMMENDED $124,657 $11,406 $12,381
227,922
kWh
$(-5,528.0) $29,118 $90,000 $(-1,314.0)
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Personnel Changes Savings Administrative Changes Savings Primary Raw Material Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs