Assessment Year | 2003 |
---|---|
Principal Product | Aluminum and plastic parts |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 35 |
Plant Area |
43,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,990
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Demand | $31,442 | 654,960 |
kW-mo/yr
|
$0.048 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $12,572 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $291 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 4.323: Optimize lot sizes to reduce inventory carrying costs | $2,625 | $80 | - | $2,625 | |
02 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $1,426 | $285 |
$1,426
20,346
kWh
|
- | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $131 | $155 |
$131
1,422
kWh
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $291 | $29 |
$291
4,157
kWh
|
- | |
05 | 2.6218: Turn off equipment when not in use | $8,099 | $169 |
$8,099
115,696
kWh
|
- | |
TOTAL RECOMMENDED | $12,572 | $718 |
$9,947
141,621
kWh
|
$2,625 | ||
TOTAL IMPLEMENTED | $291 | $29 |
$291
4,157
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs