Assessment Year | 1998 |
---|---|
Principal Product | Jet Engine Parts |
NAICS |
n/a
|
SIC | 3544: Special Dies and Tools, Die Sets, Jigs and Fixtures, and Industrial Molds |
Sales Range | $5 M to 10M |
# of Employees | 87 |
Plant Area |
75,000
ft2
|
Annual Production | 2,300
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Maine |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $99,633 | 1,362,251 |
kWh
|
$0.073 |
Electricity Demand | $7,668 | 3,121 |
kW-mo/yr
|
$2.46 |
Electricity Fees | $2,843 | - |
|
- |
LPG | $23,151 | 2,692 |
MMBtu
|
$8.60 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,175 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,334 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Other Liquid (haz) Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7244: Revise smoke cleanup from operations | $2,943 | $500 |
$2,943
42,204
kWh
|
- | - | - | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,780 | $10,015 |
$1,847
26,377
kWh
|
$933
-
kW-mo/yr
|
- | - | - | - | |
03 | 4.821: Pay bills on time to avoid late fees | $1,507 | - | - | - | - | - | $1,507 | - | |
04 | 4.821: Pay bills on time to avoid late fees | $104 | - | - | - | - | - | $104 | - | |
05 | 3.8133: Convert to aqueous cleaning | $10,101 | $46,354 |
$(-137.0)
(-2,052)
kWh
|
- |
$(-2,497.0)
-
MMBtu
|
$151
-
gal
|
- | $12,584 | |
06 | 3.5146: Utilize a central coolant system for cleaning and reuse of metal working fluid | $2,740 | $3,500 | - | - | - |
$2,740
-
gal
|
- | - | |
TOTAL RECOMMENDED | $20,175 | $60,369 |
$4,653
66,529
kWh
|
$933
-
kW-mo/yr
|
$(-2,497.0)
-
MMBtu
|
$2,891
-
gal
|
$1,611 | $12,584 | ||
TOTAL IMPLEMENTED | $7,334 | $10,515 |
$4,790
68,581
kWh
|
$933
-
kW-mo/yr
|
- | - | $1,611 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Other Liquid (haz) Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs