Assessment Year | 2006 |
---|---|
Principal Product | Jet Engine Components |
NAICS | 336412: Aircraft Engine and Engine Parts Manufacturing |
SIC | 3724: Aircraft Engines and Engine Parts |
Sales Range | $5 M to 10M |
# of Employees | 1,500 |
Plant Area |
968,000
ft2
|
Annual Production | 105,000
units
|
Production Hrs. Annual | 8,590
hrs
|
Location (State) | Maine |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,935,943 | 52,122,000 |
kWh
|
$0.056 |
Electricity Demand | $652,022 | 95,781 |
kW-mo/yr
|
$6.81 |
Electricity Fees | $19,416 | - |
|
- |
Natural Gas | $333,434 | 20,373 |
MMBtu
|
$16.37 |
Fuel Oil #6 | $822,981 | 101,093 |
MMBtu
|
$8.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $149,716 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Fuel Oil #6 Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3413: Burn fossil fuel to produce steam to drive a steam turbine-generator and use steam exhaust for heat | $46,963 | - |
$123,310
2,242,000
kWh
|
$12,133
-
kW-mo/yr
|
- |
$(-83,436.0)
-
MMBtu
|
$(-5,044.0) | |
02 | 2.7314: Reduce ventilation air | $45,943 | $10,400 |
$7,205
131,000
kWh
|
$385
-
kW-mo/yr
|
- |
$38,353
-
MMBtu
|
- | |
03 | 2.1331: Burn a less expensive grade of fuel | $14,261 | $5,500 |
$3,306
60,100
kWh
|
- |
$42,958
-
MMBtu
|
$(-32,003.0)
-
MMBtu
|
- | |
04 | 2.7314: Reduce ventilation air | $12,889 | $1,700 |
$594
10,800
kWh
|
- | - |
$12,295
-
MMBtu
|
- | |
05 | 2.8122: Use utility controlled power management | $12,223 | $14,000 |
$333
600
kWh
|
$12,000
-
kW-mo/yr
|
$(-101.0)
-
MMBtu
|
- | $(-9.0) | |
06 | 2.7311: Ventilation system to shut off when room is not in use | $10,577 | $1,870 |
$1,997
36,300
kWh
|
- | - |
$8,580
-
MMBtu
|
- | |
07 | 2.1243: Use heat from boiler blowdown to preheat boiler feed water | $6,860 | $3,500 | - | - | - |
$6,860
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $149,716 | $36,970 |
$136,745
2,480,800
kWh
|
$24,518
-
kW-mo/yr
|
$42,857
-
MMBtu
|
$(-49,351.0)
-
MMBtu
|
$(-5,053.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Fuel Oil #6 Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs