| Assessment Year | 1993 |
|---|---|
| Principal Product | plain teflon hose |
| NAICS |
n/a
|
| SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 500 |
| Plant Area |
300,000
ft2
|
| Annual Production | 600,000
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Massachusetts |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $885,331 | 9,746,483 |
kWh
|
$0.091 |
| Natural Gas | $188,729 | 54,519 |
MMBtu
|
$3.46 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $53,115 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,263 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|
| 01 | 3.4115: Recover and reuse cooling water | $31,246 | $14,546 |
$(-9,226.0)
(-101,700)
kWh
|
- |
$40,472
-
Tgal
|
|
| 02 | 2.2511: Insulate bare equipment | $12,032 | - |
$12,032
132,474
kWh
|
- | - | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,138 | $6,840 |
$5,138
56,565
kWh
|
- | - | |
| 04 | 2.2437: Recover waste heat from equipment | $2,436 | $9,790 | - |
$2,436
-
MMBtu
|
- | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,263 | - |
$2,263
24,912
kWh
|
- | - | |
| TOTAL RECOMMENDED | $53,115 | $31,176 |
$10,207
112,251
kWh
|
$2,436
-
MMBtu
|
$40,472
-
Tgal
|
||
| TOTAL IMPLEMENTED | $2,263 | - |
$2,263
24,912
kWh
|
- | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs