Assessment Year | 1986 |
---|---|
Principal Product | CUSTOM WELDED METAL PROD |
NAICS |
n/a
|
SIC | 3443: Fabricated Plate Work (Boiler Shops) |
Sales Range | $5 M to 10M |
# of Employees | 50 |
Plant Area |
n/a
|
Annual Production | 5,100,000
lb
|
Production Hrs. Annual | 4,845
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $122,463 | 1,733,001 |
kWh
|
$0.071 |
Natural Gas | $74,067 | 10,892 |
MMBtu
|
$6.80 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,339 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,339 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7231: Use radiant heater for spot heating | $721 | $800 | - |
$721
-
MMBtu
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,705 | $300 |
$6,705
94,959
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,390 | $300 |
$7,390
104,631
kWh
|
- | |
04 | 2.7494: Install storm windows and doors | $2,523 | $6,945 | - |
$2,523
-
MMBtu
|
|
TOTAL RECOMMENDED | $17,339 | $8,345 |
$14,095
199,590
kWh
|
$3,244
-
MMBtu
|
||
TOTAL IMPLEMENTED | $17,339 | $8,345 |
$14,095
199,590
kWh
|
$3,244
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs