Assessment Year | 2021 |
---|---|
Principal Product | Conveyor Plastic Belt |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | less than $500 k |
# of Employees | 263 |
Plant Area |
162,143
ft2
|
Annual Production | 16,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,181,491 | 32,942,136 |
kWh
|
$0.066 |
TOTAL YEARLY COSTS | $2,181,491 | |||
RECOMMENDED SAVINGS* | $285,200 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $285,200 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.2625: Chill water to the highest temperature possible | $35,907 | $250 |
$35,907
542,229
kWh
|
|
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,807 | $428 |
$2,807
42,386
kWh
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,440 | $900 |
$5,440
82,147
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $31,154 | $39,829 |
$31,154
470,455
kWh
|
|
05 | 2.2622: Replace existing chiller with high efficiency model | $209,892 | $1,023,215 |
$209,892
3,169,524
kWh
|
|
TOTAL RECOMMENDED | $285,200 | $1,064,622 |
$285,200
4,306,741
kWh
|
||
TOTAL IMPLEMENTED | $285,200 | $1,064,622 |
$285,200
4,306,741
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs