Assessment Year 2007
Principal Product Shears
NAICS 332215: Metal Kitchen Cookware, Utensil, Cutlery, and Flatware (except Precious) Manufacturing
SIC 3421: Cutlery
Sales Range $1
M
to 5
M
# of Employees 55
Plant Area 12,500
ft2
Annual Production 150,000
units
Production Hrs. Annual 2,000
hrs
Location (State) Arkansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $27,978 336,600
kWh
Electricity Fees $2,463 -
Natural Gas $62,503 6,218
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $9,898 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $5,716

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Fees Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,405 $1,880 $3,130
37,654
kWh
$275 - -
02 4.611: Begin a practice of predictive / preventative maintenance $2,024 $210 $482
5,800
kWh
$42 - $1,500
03 2.2511: Insulate bare equipment $1,816 $558 $1,669
20,074
kWh
$147 - -
04 2.2511: Insulate bare equipment $1,780 $1,662 $1,636
19,688
kWh
$144 - -
05 2.6211: Conserve energy by efficient use of vending machines $475 $471 $437
5,256
kWh
$38 - -
06 2.4231: Reduce the pressure of compressed air to the minimum required $287 $30 $264
3,180
kWh
$23 - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $111 $92 $83
999
kWh
$7 $21 -
TOTAL RECOMMENDED $9,898 $4,903 $7,701
92,651
kWh
$676 $21 $1,500
TOTAL IMPLEMENTED $5,716 $2,120 $3,876
46,634
kWh
$340 - $1,500
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Fees Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs