Assessment Year | 2005 |
---|---|
Principal Product | Particle board |
NAICS | 321219: Reconstituted Wood Product Manufacturing |
SIC | 2493: Reconstituted Wood Products |
Sales Range | $50 M to 100M |
# of Employees | 189 |
Plant Area |
278,000
ft2
|
Annual Production | 350,000
thousand feet
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,500,000 | 49,852,800 |
kWh
|
$0.050 |
Electricity Demand | $691,681 | 91,077 |
kW-mo/yr
|
$7.59 |
Electricity Fees | $128,454 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,264,365 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $134,684 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Wood Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3414: Burn waste to produce steam to drive a steam turbine generator set and use steam exhaust for heat | $3,092,622 | - |
$2,428,662
49,416,000
kWh
|
$546,480
-
kW-mo/yr
|
$117,480 | - | - | |
02 | 2.2511: Insulate bare equipment | $46,200 | $2,600 | - | - | - |
$46,200
-
MMBtu
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $51,555 | $15,000 |
$49,716
991,343
kWh
|
- | $1,839 | - | - | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $34,402 | $1,400 |
$27,391
546,172
kWh
|
$5,784
-
kW-mo/yr
|
$1,227 | - | - | |
05 | 2.7134: Use photocell controls | $22,793 | - |
$21,980
438,292
kWh
|
- | $813 | - | - | |
06 | 2.4239: Eliminate or reduce compressed air usage | $13,071 | - |
$12,605
251,348
kWh
|
- | $466 | - | - | |
07 | 2.7135: Install occupancy sensors | $1,195 | - |
$1,152
22,963
kWh
|
- | $43 | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,527 | $1,930 |
$885
17,643
kWh
|
- | $33 | - | $1,609 | |
TOTAL RECOMMENDED | $3,264,365 | $20,930 |
$2,542,391
51,683,761
kWh
|
$552,264
-
kW-mo/yr
|
$121,901 |
$46,200
-
MMBtu
|
$1,609 | ||
TOTAL IMPLEMENTED | $134,684 | $20,930 |
$77,992
1,555,158
kWh
|
$5,784
-
kW-mo/yr
|
$3,099 |
$46,200
-
MMBtu
|
$1,609 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Wood Savings | Personnel Changes Savings |