| Assessment Year | 2004 |
|---|---|
| Principal Product | Produce packaging |
| NAICS | 311991: Perishable Prepared Food Manufacturing |
| SIC | 2099: Food Preparations, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 250 |
| Plant Area |
250,000
ft2
|
| Annual Production | 500,000,000
lb
|
| Production Hrs. Annual | 5,928
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $690,404 | 10,890,156 |
kWh
|
$0.063 |
| Electricity Demand | $26,923 | 9,198 |
kW-mo/yr
|
$2.93 |
| Electricity Fees | $27,452 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $113,303 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $36,748 | $166,850 |
$35,437
558,951
kWh
|
- | $1,311 | - | - | |
| 02 | 2.7224: Reduce space conditioning during non-working hours | $18,385 | $1,317 |
$17,729
279,634
kWh
|
- | $656 | - | - | |
| 03 | 2.7111: Reduce illumination to minimum necessary levels | $16,090 | $6,000 |
$14,288
225,361
kWh
|
$1,228
-
kW-mo/yr
|
$574 | - | - | |
| 04 | 2.7134: Use photocell controls | $12,869 | $480 |
$12,410
195,743
kWh
|
- | $459 | - | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,715 | $640 |
$2,618
41,300
kWh
|
- | $97 | - | - | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,657 | $30 |
$2,562
40,408
kWh
|
- | $95 | - | - | |
| 07 | 2.7135: Install occupancy sensors | $2,585 | $600 |
$2,493
39,319
kWh
|
- | $92 | - | - | |
| 08 | 2.7224: Reduce space conditioning during non-working hours | $2,187 | $660 |
$2,109
33,259
kWh
|
- | $78 | - | - | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,402 | $1,225 |
$739
11,851
kWh
|
- | $27 | - | $636 | |
| 10 | 4.611: Begin a practice of predictive / preventative maintenance | $17,665 | $4,340 | - | - | - | $2,500 | $15,165 | |
| TOTAL RECOMMENDED | $113,303 | $182,142 |
$90,385
1,425,826
kWh
|
$1,228
-
kW-mo/yr
|
$3,389 | $2,500 | $15,801 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs