Assessment Year 2023
Principal Product Awnings and winstops
NAICS 314910: Textile Bag and Canvas Mills
SIC 2394: Canvas and Related Products
Sales Range $10
M
to 50
M
# of Employees 110
Plant Area 150,000
ft2
Annual Production 16,000
units
Production Hrs. Annual 4,160
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $52,729 865,829
kWh
Electricity Demand $26,479 2,970
kW-mo/yr
Electricity Fees $9,650 -
Natural Gas $61,027 7,194
MMBtu
TOTAL YEARLY COSTS $149,885
RECOMMENDED SAVINGS* $7,984 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $4,197

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.6212: Turn off equipment during breaks, reduce operating time $856 - $856
14,040
kWh
-
02 2.4231: Reduce the pressure of compressed air to the minimum required $1,461 $100 $1,217
19,951
kWh
$244
-
kW-mo/yr
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,846 $4,210 $1,407
23,065
kWh
$439
-
kW-mo/yr
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $890 $2,400 $626
10,265
kWh
$264
-
kW-mo/yr
05 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $1,345 $4,836 $946
15,517
kWh
$399
-
kW-mo/yr
06 2.7232: Replace existing hvac unit with high efficiency model $1,586 $8,304 $1,053
17,275
kWh
$533
-
kW-mo/yr
TOTAL RECOMMENDED $7,984 $19,850 $6,105
100,113
kWh
$1,879
-
kW-mo/yr
TOTAL IMPLEMENTED $4,197 $6,710 $3,250
53,281
kWh
$947
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs