| Assessment Year | 1994 |
|---|---|
| Principal Product | newspapers |
| NAICS |
n/a
|
| SIC | 2711: Newspapers: Publishing, or Publishing and Printing |
| Sales Range | $5 M to 10M |
| # of Employees | 140 |
| Plant Area |
14,778
ft2
|
| Annual Production | 11,054,000
pieces
|
| Production Hrs. Annual | 8,030
hrs
|
| Location (State) | Kansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $47,340 | 933,177 |
kWh
|
$0.051 |
| Natural Gas | $8,313 | 1,686 |
MMBtu
|
$4.93 |
| Other Gas | $16,296 | 2,336 |
MMBtu
|
$6.98 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,627 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,844 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7124: Make a practice of turning off lights when not needed | $5,398 | - |
$5,398
106,389
kWh
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,439 | $6,860 |
$2,439
48,066
kWh
|
- | - | |
| 03 | 2.7135: Install occupancy sensors | $1,844 | $2,439 |
$1,844
36,342
kWh
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $136 | $144 |
$136
879
kWh
|
- | - | |
| 05 | 2.7423: Reduce heat gain by window tinting | $714 | $2,080 |
$714
14,068
kWh
|
- | - | |
| 06 | 2.4314: Use synthetic lubricant | $763 | $2,040 |
$763
8,206
kWh
|
- | - | |
| 07 | 2.2437: Recover waste heat from equipment | $281 | $325 |
$281
1,758
kWh
|
- | - | |
| 08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $164 | $79 |
$164
3,224
kWh
|
- | - | |
| 09 | 2.4133: Use most efficient type of electric motors | $1,100 | $4,560 |
$1,100
21,688
kWh
|
- | - | |
| 10 | 2.1335: Replace gasoline with diesel, lpg, or natural gas | $4,788 | $11,794 | - |
$(-9,576.0)
-
MMBtu
|
$14,364
-
MMBtu
|
|
| TOTAL RECOMMENDED | $17,627 | $30,321 |
$12,839
240,620
kWh
|
$(-9,576.0)
-
MMBtu
|
$14,364
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $11,844 | $16,122 |
$11,844
224,794
kWh
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Other Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs