Assessment Year | 1988 |
---|---|
Principal Product | ANIMAL VACCINES, SERUMS |
NAICS |
n/a
|
SIC | 2836: Biological Products, Except Diagnostic Substances |
Sales Range | $5 M to 10M |
# of Employees | 60 |
Plant Area |
n/a
|
Annual Production | 45,000,000
pieces
|
Production Hrs. Annual | 2,460
hrs
|
Location (State) | Nebraska |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $109,860 | 2,378,957 |
kWh
|
$0.046 |
Natural Gas | $24,760 | 6,785 |
MMBtu
|
$3.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,378 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,470 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $487 | $282 |
$487
10,551
kWh
|
- | - | |
02 | 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle | $8,274 | $1,008 |
$1,854
40,152
kWh
|
$6,420
-
MMBtu
|
- | |
03 | 2.2621: Modify refrigeration system to operate at a lower pressure | $3,166 | $7,300 |
$3,166
68,581
kWh
|
- | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,624 | $100 |
$1,624
35,170
kWh
|
- | - | |
05 | 3.4115: Recover and reuse cooling water | $791 | $860 | - | - | $791 | |
06 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $1,336 | $1,300 | - |
$1,336
-
MMBtu
|
- | |
07 | 2.2437: Recover waste heat from equipment | $898 | $1,500 | - |
$898
-
MMBtu
|
- | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $406 | $580 |
$406
8,792
kWh
|
- | - | |
09 | 3.4116: Meter recycled water (to reduce sewer charges) | $396 | $580 | - | - | $396 | |
TOTAL RECOMMENDED | $17,378 | $13,510 |
$7,537
163,246
kWh
|
$8,654
-
MMBtu
|
$1,187 | ||
TOTAL IMPLEMENTED | $12,470 | $4,330 |
$3,965
85,873
kWh
|
$7,318
-
MMBtu
|
$1,187 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs