Assessment Year | 1986 |
---|---|
Principal Product | RESTAURANT BOOTH SEATING |
NAICS |
n/a
|
SIC | 2541: Wood Office and Store Fixtures, Partitions, Shelving, and Lockers |
Sales Range | $1 M to 5M |
# of Employees | 63 |
Plant Area |
n/a
|
Annual Production | 500
thousand feet
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $16,653 | 159,144 |
kWh
|
$0.10 |
Natural Gas | $6,592 | 1,451 |
MMBtu
|
$4.54 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,345 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,345 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,730 | $2,554 |
$2,730
26,084
kWh
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,331 | $380 |
$2,331
22,274
kWh
|
- | - | |
03 | 2.2532: Use only amount of air necessary to prevent explosion hazard | $449 | $14 |
$31
293
kWh
|
$418
-
MMBtu
|
- | |
04 | 2.1123: Install automatic stack damper | $440 | $700 | - |
$440
-
MMBtu
|
- | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $170 | - | - |
$350
-
MMBtu
|
$(-180.0) | |
06 | 2.7221: Lower temperature during the winter season and vice-versa | $225 | $40 |
$184
1,758
kWh
|
$41
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $6,345 | $3,688 |
$5,276
50,409
kWh
|
$1,249
-
MMBtu
|
$(-180.0) | ||
TOTAL IMPLEMENTED | $6,345 | $3,688 |
$5,276
50,409
kWh
|
$1,249
-
MMBtu
|
$(-180.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs