ITAC Assessment: KS2426
ITAC logo
ITAC Assessment: KS2426
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Carpet Backing
NAICS 314110: Carpet and Rug Mills
SIC 2273: Carpets and Rugs
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area 450,000
ft2
Annual Production 18,600,000
pieces
Production Hrs. Annual 3,060
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $395,992 2,596,005
kWh
Natural Gas $314,047 38,557
MMBtu
Waste Disposal Costs
Water Usage $10,484 2,637
Tgal
Water Disposal $11,533 2,637
Tgal
TOTAL YEARLY COSTS $732,056
RECOMMENDED SAVINGS* $120,630 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.9114: Use solar heat to make electricty $78,312 $475,144 $78,312
522,083
kWh
- -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $9,975 $5,960 $9,975
66,501
kWh
- -
03 2.4231: Reduce the pressure of compressed air to the minimum required $1,733 $150 $1,733
11,551
kWh
- -
04 2.1135: Repair furnaces and oven doors so that they seal efficiently $383 $728 - $383
-
MMBtu
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $14,414 $62,011 $10,988
73,256
kWh
- $3,426
06 2.7135: Install occupancy sensors $7,670 $12,820 $5,215
34,769
kWh
- $2,455
07 2.4133: Use most efficient type of electric motors $8,143 $67,309 $8,143
54,286
kWh
- -
TOTAL RECOMMENDED $120,630 $624,122 $114,366
762,446
kWh
$383
-
MMBtu
$5,881
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs