Assessment Year | 2021 |
---|---|
Principal Product | Pellet Ring Dies |
NAICS | 332710: Machine Shops |
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
74,080
ft2
|
Annual Production | 2,383
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $132,283 | 4,531,105 |
kWh
|
$0.029 | |
Electricity Demand | $330,515 | 13,816 |
kW-mo/yr
|
$23.92 | |
Electricity Fees | $10,365 | - |
|
- | |
Natural Gas | $23,673 | 5,196 |
MMBtu
|
$4.56 | |
Waste Disposal Costs | |||||
Water Usage | $17,057 | 3,466 |
Tgal
|
$4.92 | |
TOTAL YEARLY COSTS | $513,892 | ||||
RECOMMENDED SAVINGS* | $23,206 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $22,678 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.6211: Conserve energy by efficient use of vending machines | $528 | - |
$248
8,541
kWh
|
$280
-
kW-mo/yr
|
- | |
02 | 2.7224: Reduce space conditioning during non-working hours | $4,540 | $15 |
$374
12,912
kWh
|
- |
$4,166
-
MMBtu
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,380 | $115 |
$648
22,343
kWh
|
$732
-
kW-mo/yr
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $13,949 | $4,080 |
$13,949
481,000
kWh
|
- | - | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,770 | $3,499 |
$2,770
95,519
kWh
|
- | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $39 | $90 |
$2
65
kWh
|
$37
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $23,206 | $7,799 |
$17,991
620,380
kWh
|
$1,049
-
kW-mo/yr
|
$4,166
-
MMBtu
|
||
TOTAL IMPLEMENTED | $22,678 | $7,799 |
$17,743
611,839
kWh
|
$769
-
kW-mo/yr
|
$4,166
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs