| Assessment Year | 2013 |
|---|---|
| Principal Product | Rigid Jewelry Boxes |
| NAICS | 322212: Folding Paperboard Box Manufacturing |
| SIC | 2653: Corrugated and Solid Fiber Boxes |
| Sales Range | $10 M to 50M |
| # of Employees | 72 |
| Plant Area |
29,000
ft2
|
| Annual Production | 37,125,805
pieces
|
| Production Hrs. Annual | 2,570
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $80,412 | 629,288 |
kWh
|
$0.13 |
| Natural Gas | $5,075 | 705 |
MMBtu
|
$7.20 |
| Other Gas | $7,214 | 168 |
MMBtu
|
$42.94 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $20,031 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $17,267 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|
| 01 | 2.8114: Change rate schedules or other changes in utility service | $1,290 | - | - | $1,290 | |
| 02 | 4.812: Apply for investment incentives | $166 | - | - | $166 | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $493 | - |
$493
3,855
kWh
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $13,885 | $164 |
$13,885
108,473
kWh
|
- | |
| 05 | 2.7422: Plant trees or shrubs near windows to shield from sunlight | $668 | $715 |
$668
5,220
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,889 | $3,258 |
$2,889
22,566
kWh
|
- | |
| 07 | 2.7241: Install outside air damper / economizer on hvac unit | $640 | $957 |
$640
5,001
kWh
|
- | |
| TOTAL RECOMMENDED | $20,031 | $5,094 |
$18,575
145,115
kWh
|
$1,456 | ||
| TOTAL IMPLEMENTED | $17,267 | $3,422 |
$17,267
134,894
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs