Assessment Year | 2022 |
---|---|
Principal Product | Office Space |
NAICS | 551114: Corporate, Subsidiary, and Regional Managing Offices |
SIC | 6541: Title Abstract Offices |
Sales Range | less than $500 k |
# of Employees | 200 |
Plant Area |
104,220
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 6,783
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $169,036 | 1,791,462 |
kWh
|
$0.094 |
Natural Gas | $28,039 | 7,196 |
MMBtu
|
$3.90 |
TOTAL YEARLY COSTS | $197,075 | |||
RECOMMENDED SAVINGS* | $61,933 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $24,128 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2628: Utilize a less expensive cooling method | $8,336 | $10,000 |
$8,336
88,678
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $24,128 | $3,969 |
$24,128
256,683
kWh
|
- | |
03 | 2.7226: Use computer programs to optimize hvac performance | $29,469 | $62,532 |
$25,259
268,719
kWh
|
$4,210
-
MMBtu
|
|
TOTAL RECOMMENDED | $61,933 | $76,501 |
$57,723
614,080
kWh
|
$4,210
-
MMBtu
|
||
TOTAL IMPLEMENTED | $24,128 | $3,969 |
$24,128
256,683
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs