Assessment Year | 2006 |
---|---|
Principal Product | cold finish steel bars |
NAICS | 331221: Rolled Steel Shape Manufacturing |
SIC | 3316: Cold-Rolled Steel Sheet, Strip, and Bars |
Sales Range | $10 M to 50M |
# of Employees | 125 |
Plant Area |
143,283
ft2
|
Annual Production | 237,785,000
lb
|
Production Hrs. Annual | 4,335
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $386,738 | 6,035,918 |
kWh
|
$0.064 |
Electricity Demand | $74,091 | 16,677 |
kW-mo/yr
|
$4.44 |
Electricity Fees | $7,133 | - |
|
- |
Natural Gas | $31,273 | 3,730 |
MMBtu
|
$8.38 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $72,700 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $29,957 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $17,370 | $48,900 |
$(-931.0)
14,552
kWh
|
$(-89.0)
-
kW-mo/yr
|
$18,390
-
MMBtu
|
- | - | |
02 | 2.6218: Turn off equipment when not in use | $10,036 | - |
$10,036
156,799
kWh
|
- | - | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $15,683 | $66,529 |
$13,199
206,249
kWh
|
$2,484
-
kW-mo/yr
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,398 | $8,517 |
$849
13,286
kWh
|
$232
-
kW-mo/yr
|
- | - | $317 | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,840 | $900 |
$2,381
37,188
kWh
|
$459
-
kW-mo/yr
|
- | - | - | |
06 | 2.8114: Change rate schedules or other changes in utility service | $25,373 | - | - | - | - | $25,373 | - | |
TOTAL RECOMMENDED | $72,700 | $124,846 |
$25,534
428,074
kWh
|
$3,086
-
kW-mo/yr
|
$18,390
-
MMBtu
|
$25,373 | $317 | ||
TOTAL IMPLEMENTED | $29,957 | $75,946 |
$26,465
413,522
kWh
|
$3,175
-
kW-mo/yr
|
- | - | $317 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs