Assessment Year 2003
Principal Product Insert Molding-Automotive
NAICS 334417: Electronic Connector Manufacturing
SIC 3678: Electronic Connectors
Sales Range $10
M
to 50
M
# of Employees 370
Plant Area 82,125
ft2
Annual Production 40,000,000
pieces
Production Hrs. Annual 6,000
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $442,020 7,100,639
kWh
Electricity Demand $57,194 16,114
kW-mo/yr
Electricity Fees $6,127 -
Natural Gas $7,934 6,359
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $54,011 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $32,470

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $7,267 $44,109 $6,085
97,869
kWh
$871
-
kW-mo/yr
$375 $(-64.0)
02 2.7142: Utilize higher efficiency lamps and/or ballasts $10,851 $32,696 $10,279
163,236
kWh
$1,190
-
kW-mo/yr
$(-325.0) $(-293.0)
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,349 $3,502 $749
11,984
kWh
$58
-
kW-mo/yr
$248 $294
04 2.7135: Install occupancy sensors $3,423 $5,201 $3,325
53,436
kWh
$98
-
kW-mo/yr
- -
05 2.4133: Use most efficient type of electric motors $4,250 $3,184 $3,810
61,032
kWh
$440
-
kW-mo/yr
- -
06 2.7221: Lower temperature during the winter season and vice-versa $5,367 - $5,367
85,902
kWh
- - -
07 2.7221: Lower temperature during the winter season and vice-versa $553 - $553
8,893
kWh
- - -
08 2.6218: Turn off equipment when not in use $11,135 - $9,980
158,405
kWh
$1,155
-
kW-mo/yr
- -
09 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $9,477 $5,700 $8,511
135,840
kWh
$966
-
kW-mo/yr
- -
10 2.4322: Use or replace with energy efficient substitutes $339 $1,887 $339
5,430
kWh
- - -
TOTAL RECOMMENDED $54,011 $96,279 $48,998
782,027
kWh
$4,778
-
kW-mo/yr
$298 $(-63.0)
TOTAL IMPLEMENTED $32,470 $14,273 $29,309
467,486
kWh
$2,619
-
kW-mo/yr
$248 $294
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Ancillary Material Cost Savings