Assessment Year | 2001 |
---|---|
Principal Product | Teflon Coated Products |
NAICS |
n/a
|
SIC | 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 50 |
Plant Area |
28,000
ft2
|
Annual Production | 250,000,000
pieces
|
Production Hrs. Annual | 5,486
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $46,353 | 1,340,858 |
kWh
|
$0.035 |
Electricity Demand | $51,881 | 4,257 |
kW-mo/yr
|
$12.19 |
Electricity Fees | $12,948 | - |
|
- |
Natural Gas | $67,322 | 10,036 |
MMBtu
|
$6.71 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $84,092 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $55,116 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $16,050 | $2,125 |
$9,109
260,286
kWh
|
$6,941
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.2437: Recover waste heat from equipment | $10,195 | $25,250 | - | - |
$10,195
-
MMBtu
|
- | - | - | |
03 | 2.7224: Reduce space conditioning during non-working hours | $3,066 | $195 | - | - |
$3,066
-
MMBtu
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,387 | $18,965 |
$1,808
51,663
kWh
|
$1,579
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.7135: Install occupancy sensors | $94 | $372 |
$39
1,106
kWh
|
$55
-
kW-mo/yr
|
- | - | - | - | |
06 | 3.5316: Contract a wood pallet recycling company | $6,200 | $1,800 | - | - | - |
$6,200
-
lb
|
- | - | |
07 | 4.114: Add/modify equipment to improve drying process | $9,100 | $35,000 | - | - | - | - | $9,100 | - | |
08 | 4.521: Clear and rent existing space | $36,000 | $4,400 | - | - | - | - | - | $36,000 | |
TOTAL RECOMMENDED | $84,092 | $88,107 |
$10,956
313,055
kWh
|
$8,575
-
kW-mo/yr
|
$13,261
-
MMBtu
|
$6,200
-
lb
|
$9,100 | $36,000 | ||
TOTAL IMPLEMENTED | $55,116 | $6,720 |
$9,109
260,286
kWh
|
$6,941
-
kW-mo/yr
|
$3,066
-
MMBtu
|
- | - | $36,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs