Assessment Year | 2015 |
---|---|
Principal Product | pepperoni |
NAICS | 311612: Meat Processed from Carcasses |
SIC | 2013: Sausages and Other Prepared Meat Products |
Sales Range | $100 M to 500M |
# of Employees | 150 |
Plant Area |
133,600
ft2
|
Annual Production | 35,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $482,058 | 12,507,022 |
kWh
|
$0.039 |
Electricity Demand | $136,455 | 25,133 |
kW-mo/yr
|
$5.43 |
Electricity Fees | $25,175 | - |
|
- |
Natural Gas | $299,152 | 73,187 |
MMBtu
|
$4.09 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $37,039 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $14,595 | $2,000 | - | - |
$14,595
-
MMBtu
|
|
02 | 2.4133: Use most efficient type of electric motors | $11,796 | $2,046 |
$9,270
243,316
kWh
|
$2,526
-
kW-mo/yr
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,892 | $23,717 |
$3,981
104,487
kWh
|
$911
-
kW-mo/yr
|
- | |
04 | 2.7135: Install occupancy sensors | $2,292 | $9,026 |
$2,292
60,165
kWh
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,382 | $2,169 |
$1,084
28,454
kWh
|
$298
-
kW-mo/yr
|
- | |
06 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $1,030 | $3,629 |
$809
21,300
kWh
|
$221
-
kW-mo/yr
|
- | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $575 | $36 |
$452
11,856
kWh
|
$123
-
kW-mo/yr
|
- | |
08 | 2.1213: Direct warmest air to combustion intake | $477 | $372 | - | - |
$477
-
MMBtu
|
|
TOTAL RECOMMENDED | $37,039 | $42,995 |
$17,888
469,578
kWh
|
$4,079
-
kW-mo/yr
|
$15,072
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs