Assessment Year | 2011 |
---|---|
Principal Product | Promotional products |
NAICS | 323111: Commercial Printing (except Screen and Books) |
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $50 M to 100M |
# of Employees | 450 |
Plant Area |
280,000
ft2
|
Annual Production | 110,000,000
pieces
|
Production Hrs. Annual | 4,787
hrs
|
Location (State) | Minnesota |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $623,658 | 8,733,727 |
kWh
|
$0.071 |
Electricity Demand | $144,573 | 29,115 |
kW-mo/yr
|
$4.97 |
Natural Gas | $65,884 | 9,739 |
MMBtu
|
$6.76 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $52,080 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,898 | $1,649 |
$1,608
22,550
kWh
|
$290
-
kW-mo/yr
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,749 | $12,616 |
$11,040
130,797
kWh
|
$1,709
-
kW-mo/yr
|
- | |
03 | 2.7135: Install occupancy sensors | $2,492 | $1,078 |
$2,492
34,953
kWh
|
- | - | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $1,625 | $40 |
$1,364
19,132
kWh
|
$261
-
kW-mo/yr
|
- | |
05 | 2.4239: Eliminate or reduce compressed air usage | $10,733 | $5,500 |
$10,733
150,535
kWh
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,668 | $200 |
$7,379
103,497
kWh
|
$1,289
-
kW-mo/yr
|
- | |
07 | 2.4239: Eliminate or reduce compressed air usage | $430 | $240 |
$366
5,138
kWh
|
$64
-
kW-mo/yr
|
- | |
08 | 2.4239: Eliminate or reduce compressed air usage | $384 | $20 |
$327
4,592
kWh
|
$57
-
kW-mo/yr
|
- | |
09 | 2.2437: Recover waste heat from equipment | $13,101 | $5,000 | - | - |
$13,101
-
MMBtu
|
|
TOTAL RECOMMENDED | $52,080 | $26,343 |
$35,309
471,194
kWh
|
$3,670
-
kW-mo/yr
|
$13,101
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs