| Assessment Year | 1996 |
|---|---|
| Principal Product | tools and dies |
| NAICS |
n/a
|
| SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 225 |
| Plant Area |
250,000
ft2
|
| Annual Production | 500,000
pieces
|
| Production Hrs. Annual | 2,600
hrs
|
| Location (State) | Minnesota |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $113,406 | 3,239,449 |
kWh
|
$0.035 |
| Electricity Demand | $7,128 | 10,284 |
kW-mo/yr
|
$0.69 |
| Natural Gas | $67,129 | 23,297 |
MMBtu
|
$2.88 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,841 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $873 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Water Disposal Savings | Solid Waste (haz) Savings |
|---|---|---|---|---|---|---|---|
| 01 | 3.1161: Eliminate/reduce an operation | $3,833 | $2,450 | - | - |
$3,833
-
lb
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,256 | $11,497 |
$2,256
64,478
kWh
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $230 | $384 |
$230
6,448
kWh
|
- | - | |
| 04 | 3.4151: Minimize water usage | $1,649 | - | - |
$1,649
-
Tgal
|
- | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $873 | $328 |
$873
24,912
kWh
|
- | - | |
| TOTAL RECOMMENDED | $8,841 | $14,659 |
$3,359
95,838
kWh
|
$1,649
-
Tgal
|
$3,833
-
lb
|
||
| TOTAL IMPLEMENTED | $873 | $328 |
$873
24,912
kWh
|
- | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs