Assessment Year | 1994 |
---|---|
Principal Product | automotive parts |
NAICS |
n/a
|
SIC | 3465: Automotive Stampings |
Sales Range | $10 M to 50M |
# of Employees | 169 |
Plant Area |
122,000
ft2
|
Annual Production | 40,000,000
lb
|
Production Hrs. Annual | 6,552
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $250,542 | 3,357,269 |
kWh
|
$0.075 |
Natural Gas | $36,768 | 7,855 |
MMBtu
|
$4.68 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $43,902 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $32,880 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $15,282 | $700 |
$15,282
204,865
kWh
|
|
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $8,892 | $25 |
$8,892
119,285
kWh
|
|
03 | 2.4133: Use most efficient type of electric motors | $10,531 | $23,395 |
$10,531
141,266
kWh
|
|
04 | 2.6218: Turn off equipment when not in use | $3,508 | - |
$3,508
46,893
kWh
|
|
05 | 2.7135: Install occupancy sensors | $2,573 | $3,344 |
$2,573
34,584
kWh
|
|
06 | 2.7111: Reduce illumination to minimum necessary levels | $2,130 | - |
$2,130
28,429
kWh
|
|
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $986 | $76 |
$986
13,189
kWh
|
|
TOTAL RECOMMENDED | $43,902 | $27,540 |
$43,902
588,511
kWh
|
||
TOTAL IMPLEMENTED | $32,880 | $27,515 |
$32,880
440,797
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs