Assessment Year | 1998 |
---|---|
Principal Product | textile Dyeing |
NAICS |
n/a
|
SIC | 2269: Finishers of Textiles, Not elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 215 |
Plant Area |
175,000
ft2
|
Annual Production | 6,500,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $418,107 | 7,229,777 |
kWh
|
$0.058 |
Electricity Demand | $113,817 | 16,120 |
kW-mo/yr
|
$7.06 |
Electricity Fees | $(-11,197.0) | - |
|
- |
Natural Gas | $495,761 | 136,443 |
MMBtu
|
$3.63 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $167,530 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $79,332 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $19,328 | $30,330 |
$15,347
253,810
kWh
|
$3,981
-
kW-mo/yr
|
- | |
02 | 2.7135: Install occupancy sensors | $5,886 | $2,000 |
$5,886
101,700
kWh
|
- | - | |
03 | 2.4133: Use most efficient type of electric motors | $3,021 | $5,131 |
$3,021
52,169
kWh
|
- | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,188 | $50 |
$1,878
32,532
kWh
|
$310
-
kW-mo/yr
|
- | |
05 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $8,531 | $3,500 | - |
$8,531
-
kW-mo/yr
|
- | |
06 | 2.2511: Insulate bare equipment | $383 | $190 | - | - |
$383
-
MMBtu
|
|
07 | 2.2414: Use waste heat from hot flue gases to preheat | $54,070 | $24,050 | - | - |
$54,070
-
MMBtu
|
|
08 | 2.1233: Analyze flue gas for proper air/fuel ratio | $64,007 | $2,200 | - | - |
$64,007
-
MMBtu
|
|
09 | 2.7221: Lower temperature during the winter season and vice-versa | $10,116 | $1,000 | - | - |
$10,116
-
MMBtu
|
|
TOTAL RECOMMENDED | $167,530 | $68,451 |
$26,132
440,211
kWh
|
$12,822
-
kW-mo/yr
|
$128,576
-
MMBtu
|
||
TOTAL IMPLEMENTED | $79,332 | $8,381 |
$4,899
84,701
kWh
|
$310
-
kW-mo/yr
|
$74,123
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs