| Assessment Year | 2019 | 
|---|---|
| Principal Product | Animal Health Vaccines | 
| NAICS | 325412: Pharmaceutical Preparation Manufacturing | 
| SIC | 2834: Pharmaceutical Preparations | 
| Sales Range | $50 M  to 100M  | 
    
| # of Employees | 233 | 
| Plant Area | 
                            235,000
                 
ft2
 
                     | 
    
| Annual Production | 38,000,000,000
             
units
 
         | 
    
| Production Hrs. Annual | 3,120
             
hrs
 
         | 
    
| Location (State) | Georgia | 
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,168,433 | 12,201,618 | 
             
kWh
 
         | 
        $0.096 | 
| Natural Gas | $215,688 | 29,228 | 
             
MMBtu
 
         | 
        $7.38 | 
| TOTAL YEARLY COSTS | $1,384,121 | |||
| RECOMMENDED SAVINGS* | $357,990 | 
             See individual recommendations below 
            *Non-energy impacts included in savings.
         | 
    ||
| IMPLEMENTED SAVINGS* | $42,870 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | 
|---|---|---|---|---|---|---|
| 01 | 2.2625: Chill water to the highest temperature possible | $2,153 | $250 | 
                        $2,153
                                                     22,426
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| 02 | 2.2511: Insulate bare equipment | $2,334 | $1,238 | - | 
                        $2,334
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    |
| 03 | 2.2492: Use "heat wheel" or other heat exchanger to cross-exchange building exhaust air with make-up air | $9,210 | $19,899 | 
                        $9,210
                                                     95,932
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| 04 | 2.5195: Change product design to reduce energy requirements | $305,911 | $903,775 | 
                        $305,911
                                                     3,186,577
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| 05 | 2.7492: Use proper thickness of insulation on building envelope | $445 | $2,770 | 
                        $445
                                                     4,633
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| 06 | 2.9113: Use solar heat for heat | $37,938 | $246,597 | 
                        $37,938
                                                     395,164
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| TOTAL RECOMMENDED | $357,990 | $1,174,529 | 
                        $355,656
                                                     3,704,732
                                 
                                            
kWh
 
                             | 
                                                                                
                        $2,334
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    ||
| TOTAL IMPLEMENTED | $42,870 | $250,856 | 
                        $40,536
                                                     422,223
                                 
                                            
kWh
 
                             | 
                                                                                
                        $2,334
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs