Assessment Year | 2019 |
---|---|
Principal Product | Animal Health Vaccines |
NAICS | 325412: Pharmaceutical Preparation Manufacturing |
SIC | 2834: Pharmaceutical Preparations |
Sales Range | $50 M to 100M |
# of Employees | 233 |
Plant Area |
235,000
ft2
|
Annual Production | 38,000,000,000
units
|
Production Hrs. Annual | 3,120
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,168,433 | 12,201,618 |
kWh
|
$0.096 |
Natural Gas | $215,688 | 29,228 |
MMBtu
|
$7.38 |
TOTAL YEARLY COSTS | $1,384,121 | |||
RECOMMENDED SAVINGS* | $357,990 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $42,870 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2625: Chill water to the highest temperature possible | $2,153 | $250 |
$2,153
22,426
kWh
|
- | |
02 | 2.2511: Insulate bare equipment | $2,334 | $1,238 | - |
$2,334
-
MMBtu
|
|
03 | 2.2492: Use "heat wheel" or other heat exchanger to cross-exchange building exhaust air with make-up air | $9,210 | $19,899 |
$9,210
95,932
kWh
|
- | |
04 | 2.5195: Change product design to reduce energy requirements | $305,911 | $903,775 |
$305,911
3,186,577
kWh
|
- | |
05 | 2.7492: Use proper thickness of insulation on building envelope | $445 | $2,770 |
$445
4,633
kWh
|
- | |
06 | 2.9113: Use solar heat for heat | $37,938 | $246,597 |
$37,938
395,164
kWh
|
- | |
TOTAL RECOMMENDED | $357,990 | $1,174,529 |
$355,656
3,704,732
kWh
|
$2,334
-
MMBtu
|
||
TOTAL IMPLEMENTED | $42,870 | $250,856 |
$40,536
422,223
kWh
|
$2,334
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs