ITAC Assessment: GT0911
ITAC logo
ITAC Assessment: GT0911
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2018
Principal Product Vinyl Sea Wall Material
NAICS 326199: All Other Plastics Product Manufacturing
SIC 3083: Laminated Plastics Plate, Sheet, and Profile Shapes
Sales Range $10
M
to 50
M
# of Employees 35
Plant Area 92,000
ft2
Annual Production 100,000
units
Production Hrs. Annual 6,000
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $225,701 3,761,687
kWh
Natural Gas $17,230 2,402
MMBtu
TOTAL YEARLY COSTS $242,931
RECOMMENDED SAVINGS* $18,280 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $17,097

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.6212: Turn off equipment during breaks, reduce operating time $1,183 $180 $1,183
19,719
kWh
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $8,999 $3,000 $8,999
140,616
kWh
03 2.2625: Chill water to the highest temperature possible $310 $180 $310
5,173
kWh
04 2.7142: Utilize higher efficiency lamps and/or ballasts $7,788 $5,633 $7,788
129,801
kWh
TOTAL RECOMMENDED $18,280 $8,993 $18,280
295,309
kWh
TOTAL IMPLEMENTED $17,097 $8,813 $17,097
275,590
kWh
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs