Assessment Year | 2004 |
---|---|
Principal Product | TEXTILE FRABRICS |
NAICS | 315190: Other Apparel Knitting Mills |
SIC | 2253: Knit Outerwear Mills |
Sales Range | $10 M to 50M |
# of Employees | 152 |
Plant Area |
145,000
ft2
|
Annual Production | 60,000
thousand feet
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $390,497 | 11,393,729 |
kWh
|
$0.034 |
Electricity Demand | $183,233 | 20,927 |
kW-mo/yr
|
$8.76 |
Electricity Fees | $27,034 | - |
|
- |
Natural Gas | $529,116 | 103,836 |
MMBtu
|
$5.10 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $162,266 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $55,108 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.2135: Repair and eliminate steam leaks | $21,335 | $10,000 | - | - |
$20,935
-
MMBtu
|
- |
$400
-
Tgal
|
|
02 | 2.1113: Reduce combustion air flow to optimum | $19,495 | $3,060 |
$1,010
36,800
kWh
|
$1,335
-
kW-mo/yr
|
$17,150
-
MMBtu
|
- | - | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $5,050 | $616 |
$2,627
95,892
kWh
|
$2,423
-
kW-mo/yr
|
- | - | - | |
04 | 2.2113: Repair or replace steam traps | $9,228 | $11,000 | - | - |
$9,080
-
MMBtu
|
- |
$148
-
Tgal
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $21,100 | $75,700 |
$8,850
320,600
kWh
|
$12,250
-
kW-mo/yr
|
- | - | - | |
06 | 2.2622: Replace existing chiller with high efficiency model | $41,148 | $96,250 |
$13,153
482,100
kWh
|
$20,960
-
kW-mo/yr
|
- | $7,035 | - | |
07 | 2.7241: Install outside air damper / economizer on hvac unit | $5,310 | $8,000 |
$5,310
267,969
kWh
|
- | - | - | - | |
08 | 2.1111: Control pressure on steamer operations | $39,600 | $32,100 | - | - |
$39,600
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $162,266 | $236,726 |
$30,950
1,203,361
kWh
|
$36,968
-
kW-mo/yr
|
$86,765
-
MMBtu
|
$7,035 |
$548
-
Tgal
|
||
TOTAL IMPLEMENTED | $55,108 | $24,676 |
$3,637
132,692
kWh
|
$3,758
-
kW-mo/yr
|
$47,165
-
MMBtu
|
- |
$548
-
Tgal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs