ITAC Assessment: GT0792
ITAC logo
ITAC Assessment: GT0792
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2004
Principal Product TEXTILE FRABRICS
NAICS 315190: Other Apparel Knitting Mills
SIC 2253: Knit Outerwear Mills
Sales Range $10
M
to 50
M
# of Employees 152
Plant Area 145,000
ft2
Annual Production 60,000
thousand feet
Production Hrs. Annual 6,000
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $390,497 11,393,729
kWh
Electricity Demand $183,233 20,927
kW-mo/yr
Electricity Fees $27,034 -
Natural Gas $529,116 103,836
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $162,266 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $55,108

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings Water Consumption Savings
01 2.2135: Repair and eliminate steam leaks $21,335 $10,000 - - $20,935
-
MMBtu
- $400
-
Tgal
02 2.1113: Reduce combustion air flow to optimum $19,495 $3,060 $1,010
36,800
kWh
$1,335
-
kW-mo/yr
$17,150
-
MMBtu
- -
03 2.7111: Reduce illumination to minimum necessary levels $5,050 $616 $2,627
95,892
kWh
$2,423
-
kW-mo/yr
- - -
04 2.2113: Repair or replace steam traps $9,228 $11,000 - - $9,080
-
MMBtu
- $148
-
Tgal
05 2.7142: Utilize higher efficiency lamps and/or ballasts $21,100 $75,700 $8,850
320,600
kWh
$12,250
-
kW-mo/yr
- - -
06 2.2622: Replace existing chiller with high efficiency model $41,148 $96,250 $13,153
482,100
kWh
$20,960
-
kW-mo/yr
- $7,035 -
07 2.7241: Install outside air damper / economizer on hvac unit $5,310 $8,000 $5,310
267,969
kWh
- - - -
08 2.1111: Control pressure on steamer operations $39,600 $32,100 - - $39,600
-
MMBtu
- -
TOTAL RECOMMENDED $162,266 $236,726 $30,950
1,203,361
kWh
$36,968
-
kW-mo/yr
$86,765
-
MMBtu
$7,035 $548
-
Tgal
TOTAL IMPLEMENTED $55,108 $24,676 $3,637
132,692
kWh
$3,758
-
kW-mo/yr
$47,165
-
MMBtu
- $548
-
Tgal
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings Water Consumption Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs