| Assessment Year | 1993 |
|---|---|
| Principal Product | Men's Slacks |
| NAICS |
n/a
|
| SIC | 2325: Men's and Boys' Separate Trousers and Slacks |
| Sales Range | $1 M to 5M |
| # of Employees | 175 |
| Plant Area |
40,000
ft2
|
| Annual Production | 240,000
pieces
|
| Production Hrs. Annual | 2,040
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $78,068 | 748,242 |
kWh
|
$0.10 |
| Natural Gas | $21,395 | 4,112 |
MMBtu
|
$5.20 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,030 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,190 | $7,340 |
$3,190
31,360
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,710 | $22,550 |
$4,710
45,721
kWh
|
- | |
| 03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,840 | - | - |
$1,840
-
MMBtu
|
|
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $280 | - |
$280
2,638
kWh
|
- | |
| 05 | 2.4131: Size electric motors for peak operating efficiency | $3,010 | $6,250 |
$3,010
28,722
kWh
|
- | |
| TOTAL RECOMMENDED | $13,030 | $36,140 |
$11,190
108,441
kWh
|
$1,840
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs