Assessment Year | 1992 |
---|---|
Principal Product | LEAD-ACID BATTERIES |
NAICS |
n/a
|
SIC | 3691: Storage Batteries |
Sales Range | $10 M to 50M |
# of Employees | 400 |
Plant Area |
n/a
|
Annual Production | 2,700,000
pieces
|
Production Hrs. Annual | 6,480
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,556,211 | 51,004,690 |
kWh
|
$0.050 |
Natural Gas | $105,001 | 27,450 |
MMBtu
|
$3.83 |
LPG | $10,063 | 1,610 |
MMBtu
|
$6.25 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $51,175 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $51,175 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.2443: Re-use or recycle hot or cold process exhaust air | $11,700 | - |
$11,700
233,294
kWh
|
- | |
02 | 2.7229: Air condition only space necessary | $11,100 | $9,000 |
$11,100
220,985
kWh
|
- | |
03 | 2.7221: Lower temperature during the winter season and vice-versa | $6,920 | $520 |
$6,920
137,749
kWh
|
- | |
04 | 2.4133: Use most efficient type of electric motors | $6,033 | $170,330 |
$6,033
120,457
kWh
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $11,647 | - |
$11,647
232,415
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,155 | $7,320 |
$1,750
34,877
kWh
|
$(-595.0) | |
07 | 2.7111: Reduce illumination to minimum necessary levels | $2,620 | - |
$2,620
52,169
kWh
|
- | |
TOTAL RECOMMENDED | $51,175 | $187,170 |
$51,770
1,031,946
kWh
|
$(-595.0) | ||
TOTAL IMPLEMENTED | $51,175 | $187,170 |
$51,770
1,031,946
kWh
|
$(-595.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs