Assessment Year | 1987 |
---|---|
Principal Product | HEAT EXCHANGERS & DRUMS |
NAICS |
n/a
|
SIC | 3443: Fabricated Plate Work (Boiler Shops) |
Sales Range | $5 M to 10M |
# of Employees | 120 |
Plant Area |
n/a
|
Annual Production | 12,000,000
lb
|
Production Hrs. Annual | 2,704
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $115,931 | 1,213,951 |
kWh
|
$0.095 |
Natural Gas | $21,379 | 4,029 |
MMBtu
|
$5.31 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,140 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,066 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $616 | $644 |
$616
6,448
kWh
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,314 | $3,240 |
$2,314
24,326
kWh
|
- | |
03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,760 | $400 | - |
$1,760
-
MMBtu
|
|
04 | 2.2511: Insulate bare equipment | $160 | $500 | - |
$160
-
MMBtu
|
|
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,290 | $450 |
$8,290
87,925
kWh
|
- | |
TOTAL RECOMMENDED | $13,140 | $5,234 |
$11,220
118,699
kWh
|
$1,920
-
MMBtu
|
||
TOTAL IMPLEMENTED | $9,066 | $1,594 |
$8,906
94,373
kWh
|
$160
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs