| Assessment Year | 1986 |
|---|---|
| Principal Product | PACKAGED CHICKEN |
| NAICS |
n/a
|
| SIC | 2015: Poultry Slaughtering and Processing |
| Sales Range | $10 M to 50M |
| # of Employees | 500 |
| Plant Area |
n/a
|
| Annual Production | 32,000,000
pieces
|
| Production Hrs. Annual | 3,500
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $579,178 | 11,837,046 |
kWh
|
$0.049 |
| Natural Gas | $237,825 | 50,238 |
MMBtu
|
$4.73 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $34,516 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $33,454 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2511: Insulate bare equipment | $818 | $2,688 | - |
$818
-
MMBtu
|
|
| 02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $1,563 | - |
$1,563
-
kWh
|
- | |
| 03 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $20,878 | $34,000 | - |
$20,878
-
MMBtu
|
|
| 04 | 2.4133: Use most efficient type of electric motors | $574 | $983 |
$574
11,723
kWh
|
- | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,032 | $4,245 |
$1,032
21,102
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $488 | $219 |
$488
9,965
kWh
|
- | |
| 07 | 2.8114: Change rate schedules or other changes in utility service | $9,163 | $3,000 |
$9,163
-
kWh
|
- | |
| TOTAL RECOMMENDED | $34,516 | $45,135 |
$12,820
42,790
kWh
|
$21,696
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $33,454 | $43,933 |
$11,758
21,102
kWh
|
$21,696
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs