Assessment Year | 1984 |
---|---|
Principal Product | CARPETS |
NAICS |
n/a
|
SIC | 2273: Carpets and Rugs |
Sales Range | $100 M to 500M |
# of Employees | 275 |
Plant Area |
n/a
|
Annual Production | 22,200,000
thousand feet
|
Production Hrs. Annual | 4,500
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $168,648 | 3,521,981 |
kWh
|
$0.048 |
Natural Gas | $499,412 | 98,239 |
MMBtu
|
$5.08 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $187,186 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,272 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $14,600 | $500 | - |
$14,600
-
MMBtu
|
|
02 | 2.5191: Modify dye beck | $77,000 | $100,000 |
$(-24,000.0)
(-498,242)
kWh
|
$101,000
-
MMBtu
|
|
03 | 2.5191: Modify dye beck | $23,700 | - | - |
$23,700
-
MMBtu
|
|
04 | 2.5191: Modify dye beck | $7,435 | $60,000 | - |
$7,435
-
MMBtu
|
|
05 | 2.5191: Modify dye beck | $7,227 | $15,000 | - |
$7,227
-
MMBtu
|
|
06 | 2.5192: Modify textile dryers | $24,720 | $20,000 | - |
$24,720
-
MMBtu
|
|
07 | 2.1243: Use heat from boiler blowdown to preheat boiler feed water | $11,360 | $10,000 | - |
$11,360
-
MMBtu
|
|
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,672 | $5,000 |
$3,672
76,788
kWh
|
- | |
09 | 2.3191: Use demand controller or load shedder | $17,472 | $40,000 |
$17,472
-
kWh
|
- | |
TOTAL RECOMMENDED | $187,186 | $250,500 |
$(-2,856.0)
(-421,454)
kWh
|
$190,042
-
MMBtu
|
||
TOTAL IMPLEMENTED | $18,272 | $5,500 |
$3,672
76,788
kWh
|
$14,600
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs