| Assessment Year | 1982 |
|---|---|
| Principal Product | RECONDITIONED STEEL DRUM |
| NAICS |
n/a
|
| SIC | 3412: Metal Shipping Barrels, Drums, Kegs, and Pails |
| Sales Range | $1 M to 5M |
| # of Employees | 82 |
| Plant Area |
n/a
|
| Annual Production | 3,557,800
pieces
|
| Production Hrs. Annual | 1,800
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $61,979 | 1,016,120 |
kWh
|
$0.061 |
| Natural Gas | $155,254 | 38,985 |
MMBtu
|
$3.98 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $19,442 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $19,442 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $8,768 | $500 | - |
$8,768
-
MMBtu
|
|
| 02 | 2.2136: Install / repair insulation on steam lines | $4,227 | $2,513 | - |
$4,227
-
MMBtu
|
|
| 03 | 2.2212: Use minimum safe oven ventilation | $4,221 | $22 |
$655
10,844
kWh
|
$3,566
-
MMBtu
|
|
| 04 | 2.2135: Repair and eliminate steam leaks | $1,084 | $180 | - |
$1,084
-
MMBtu
|
|
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,142 | $150 |
$1,142
18,757
kWh
|
- | |
| TOTAL RECOMMENDED | $19,442 | $3,365 |
$1,797
29,601
kWh
|
$17,645
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $19,442 | $3,365 |
$1,797
29,601
kWh
|
$17,645
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs